What should be noted during the use of oxygen generator

1.Quality oxygen generator has "four fears" - fear of fire, fear of heat, fear of dust, fear of moisture. Therefore, when using the oxygen machine, remember to keep away from fire, avoid direct light (sunlight), high temperature environment; usually pay attention to the nasal catheter, oxygen catheter, humidification heating device and other replacement and cleaning and disinfection to prevent cross infection, catheter blockage; oxygen machine idle for a long time without use, should cut off the power, pour out the water in the humidification bottle, wipe clean the surface of the oxygen machine, with a plastic cover, placed in a sunless The water in the wetting cup should be poured out before transporting the machine. The water or moisture in the oxygen concentrator will damage important accessories (such as molecular sieve, compressor, gas control valve, etc.).
2. When the oxygen concentrator is running, remember to ensure the voltage is stable, the voltage is too high or too low will burn the instrument. So the regular manufacturers will be equipped with intelligent monitoring of low-voltage, high-voltage alarm system, and power supply seat with a fuse box. For remote rural areas, the line is old and aging old neighborhoods, or industrial areas of users, it is recommended to buy a voltage regulator.
3. Quality oxygen generator that meet medical standards have the technical performance of 24-hour uninterrupted operation, so the oxygen concentrator should be used every day. If you go out for a short time, you need to turn off the flow meter, pour out the water in the wetting cup, cut off the power supply and place it in a dry and ventilated place.
4. When the oxygen concentrator is in use, ensure that the bottom exhaust is smooth, so do not put foam, carpets and other items that are not easy to dissipate heat and exhaust, and should not be placed in a narrow, unventilated area.
5. Oxygen machine humidification device, commonly known as: wet bottle, wet cup of water recommended the use of cool white water, distilled water, pure water as far as possible, do not use tap water, mineral water, to avoid the generation of scale. The water level should not exceed the highest scale to prevent inflow into the oxygen conduit, the wetting bottle interface should be tightened to prevent oxygen leakage.
6. The primary filter and secondary filter system of oxygen generator should be cleaned and replaced regularly.
7、The molecular sieve oxygen generator is not used for a long time, it will reduce the activity of molecular sieve, so attention should be paid to the operation and maintenance of the machine.